3.6V Sanyo UR18650A

UR18650A

Sanyo UR18650A cell is a wonderful cell with minimal nominal capacity of 2150mAh and nominal voltage of 3.6V.  Many electric devices can be powered by Sanyo UR18650A cells. It has stable discharge voltage and light weight. This is a top-in class choice in 18650 cells.

HIGHLIGHTS OF Sanyo UR18650A

  • Positive Terminal: Flat Top
  • Nominal Capacity: Min.2150mAh
  • Nominal Voltage: 3.6V
  • Internal resistance:≤100mΩ
  • Charging Method: CCCV(Constant Current Constant Voltage)
  • Charging Voltage: 4.2V
  • Charging Current: std.1505mAh
  • Charging Time: 3.0hrs.
  • Energy Density: 464Wh/l     180Wh/kg

APPLICATION: Portable equipment like Laptop,pad, digital camera…etc. Military equipment like IR telescop, Medical devices and Power tools…

Featurea:

1.) high capacity and stable discharge voltage
2.)light weight, small size and high performance
3.)small internal resistance
4.)outstanding discharge  properties and storage Capacity
5.)Environment friendly
6.)long cycle life
7.)none memory effect

APPEARANCE

Shape:                    Cylindrical
Can :                       Steel
Diameter :            Max. 18.05mm(bare cell)
Height :                 Max. 64.70mm(bare cell)
Weight:                 Max.43.0g

outline dimension of Sanyo ur18650a

Nominal Specification of UR18650A

Item Specifications Notes
Nominal Capacity (Min.) 2150 mAh 0.2CA discharge
Typical Capacity 2250 mAh 0.2CA discharge
Nominal Voltage 3.6 V -
End Voltage 3.0 V -
Charging Current (Std.) 1.51 A 0 ~ +40℃
Charging Voltage 4.20±0.03V -
Charging Time (Std.) 3 hours -
Discharging Current (Std.) 2.15 A 20 ~ +60℃
Discharging Current (Max.) 4.30 A 0 ~ +40℃
Internal Resistance ≤ 100mΩ AC impedance 1 kHz
Weight ≤ 43g -
Surroudings temperature range for shipped battery ≤ 1 month -20~+60°C Percentage of recoverable capacity 80 percent
≤ 3 months -20~+45°C
≤ 1 year -20~+20°C

Electrical Characteristics Tests

Test Method Criterion
Full Charge The charger supply 1.51A constant current until battery voltage reaches 4.20V, then be changed at constant voltage of 4.20V while tapering the charge current. Charging time is 3.0 hours in all.
Capacity ①Within 1hour after fully charged, discharge at 0.2C(=0.43)A continuously down to 3.0V end
voltage.

②Within 1hour after fully charged, discharge at 1.0C(=2.15)A continuously down to 3.0V end voltage.
≥ 300min.


≥ 54min.
Cycle Life A battery unit shall be repeated 300 charge/discharge cycles, charged at CC-CV (1.51A-4.20V) for 3.0hours, discharged at 2.15A to 3.0V end voltage. After 300cycles, discharging
time is measured as specified in paragraph 4.2②.
≥ 38min.
Temperature Characteristics ①Within 1hour after fully charged at 20℃, a battery unit is stored at 0℃. Discharge time is measured by discharging at 2.15A continuously down to 3.0V end voltage.


②Within 1hour after fully charged at 20℃,a battery unit is stored at 60 ℃ . Discharge time is
measured by discharging at 2.15A continuously down to 3.0V end voltage.
≥ 30min.


≥ 50min.
Storage at Fully Charged State ①After fully charged, stored for 10days at 60℃ and rested at room temperature for 1hour. Discharge time is measured by discharging at 2.15A continuously down to 3.0V end voltage.

Then next discharge time is measured as specified in paragraph 4.2 ②.

②After fully charged, stored for 20days at 60℃ and rested at room temperature for 1hour.
Discharge time is measured by discharging at 2.15A continuously down to 3.0V end voltage.

Then next discharge time is measured as specified in paragraph 4.2 ②.
≥ 35min.


≥ 45min


≥ 30min.


≥ 40min
Storage at Fully Discharged State After fully charged and discharged as specified in paragraph 4.2 ②, then store for 20days at 60℃ and rest at room temperature for 1hour. Discharging time is measured as specified in paragraph 4.2 ②. ≥ 50min
Drop The cell is freely dropped 6 times from a height of 1m onto a flat surface of hard wood. No rupture, no fire

STANDARD TEST CONDITIONS:

The battery used for the test mentioned above should be new one delivered a week before at most. The test shall be performed at 20±2℃(Standard temperature of fifth grade adopted in JIS Z 8703(Standard Test Conditions)), 65±5%(Standard humidity of twentieth grade adopted in JIS Z 8703(Standard Test Conditions)). It is allowed however to test at 15~25℃, 45~85% humidity, as long as there is no big difference in test results. The battery used for the test without residual capacity indicator. The grade of voltmeter and ammeter used in the test shall be higher than class 0.5 adopted in JIS C 1102(Electric Indicator).

Storage Measures For Factory

1.Cell or battery warehouses should be set up independently.
Set up “No Fireworks” eye-catching signs in storage places.
It is strictly forbidden to stack combustibles and flammable items around.

2.The temperature of cell or battery warehouses should be controlled within the range of 20±5℃,
The maximum should not exceed 30℃,
The relative humidity should not be greater than 75%.
Keep the warehouse clean, dry and well ventilated, and do not store other items.

3.Cell or battery warehouses should be equipped with smoke and temperature alarm devices, and the alarm signal should be transmitted to a place where someone is on duty 24 hours a day.

4.Cell or battery warehouses should be equipped with independent external accident exhaust devices.
The accident exhaust devices should be interlocked with smoke and temperature alarm devices.

5.Cells and batteries should be neatly placed, not stacked too high, and storage facilities should be made of non-combustible materials, and anti-static measures should be taken.

6.The positive or negative pole position of each battery (cell) must be insulated to prevent short circuit protection measures.

7.Automatic sprinkler facilities should be set up in the battery warehouse.

8.The battery must not be stored at full capacity, and it is recommended to store it at 50% power.

9.Semi-finished batteries should be equipped with protective plates.

10.Waste batteries should be stored separately after being discharged.

11.Each fireproof zone of the battery and cell warehouse shall not exceed 250 square meters.

12.A sufficient number of spherical dry powder automatic fire extinguishers or sprinklers should be hung in the battery and cell warehouses.

13.The battery and cell warehouses should be equipped with 2 fire blankets each, and 1 special bucket for handling accident batteries.

PS:
1.Explosion-proof electrical equipment should be used in battery warehouses and aging rooms.
2.Faulty batteries and waste batteries must be placed in special treatment cabinets for isolation and disposal, and the use of explosion-proof sand buckets to deal with accident batteries is advocated.

Storage Measures For Daily Lithium Battery Users

1. For Lithium-ion batteries which need to be stored for a long time and not used, they should be kept in a state of 50%-60% charge. They should be recharged every 3 months and recharged every half a year.

2. Attention should be paid to moisture-proof and moisture-proof, to prevent squeezing, collision, etc., to avoid battery damage.

3. It is forbidden to use or place the battery at high temperatures (in hot sunlight or in very hot cars), otherwise it may cause the battery to overheat, catch fire or fail in function, and shorten its life.

4. It is forbidden to store in places with strong static electricity and strong magnetic fields, otherwise it will easily destroy the battery safety protection device and bring unsafe hidden dangers.

5. If the battery emits an odor, fever, discoloration, deformation, or any abnormality during use, storage, or charging, immediately remove the battery from the device or charger and disable it.

Charge Characteristics for UR18650A

How to Custom 18650 Battery Pack

We have the unique ability to develop custom 18650 battery pack to fit your needs. Our expert team of chemists, engineers, and manufacturers who use proven chemistry and production methods that will get from spec to production fast. Slim, flexible, more powerful.

WHAT WE CUSTOM

  • Custom Voltage Range: 3V ~ 120V
  • Custom Discharge Current: 0.2C ~ 120C (0.01A-1000A)

  • Custom BMS: Size, Features, Communication, Cut-off, Temperature
  • Custom Battery Size: Starting 0.5mm Thickness
  • Battery Temperature from -40°C–85°C
  • Custom Connector: JST/Molex/Hirose/Anderson/TE/Amphenol  Etc

WHY CHOOSE US

  • Custom 18650 Battery Pack, MOQ 100 pcs
  • Custom Samples as fast as 3 Days
  • Strict Quality Control, No Safety Concerns Ever
  • Instant Customer Support, Solve Any Problem in Time.
custom lithium battery packs collection

custom lithium battery packs collection

3.6V SAMSUNG 18650 BATTERY CELLS

3.6V SAMSUNG & Molicel 18650 BATTERY CELLS

3.6V LG 18650 BATTERY CELLS

3.6V PANASONIC & SANYO 18650 BATTERY CELLS